ASNT Liquid Penetrant Testing - Level I & II Practice Questions — 10 Free (2026)
Answer them, then check the reasoning and the clause each one comes from. No account, no card, nothing to dismiss.
ASNT PT I-II at a glance
- Question bank
- 630 questions
- Mock papers
- 5 full-length
- Figures and exhibits
- 23
- This sample
- 10 closed book
The ten questions below draw on ASTM E1417, ASTM E165, ASME V, ASTM E1316, ISO 3452.4, ISO 3452.2, ISO 3452.1 and ISO 3452.5.
Common questions
- Do I need an account to try these?
- No. The ten questions on this page are open to anyone — no registration, no card. An account is only needed for the full bank.
- What does “the clause it comes from” mean?
- Every answer names the publication and the paragraph the rule sits in, so you can find it in your own copy rather than taking our word for it. That is the habit the open-book part of these exams rewards.
- How large is the full ASNT PT I-II bank?
- 630 questions, including 5 full-length mock papers, with 23 figures and exhibits.
- Only the first answer counts — why?
- In study mode a question you have already seen the key for cannot improve your record. It keeps the progress figures, and the certificate they lead to, worth something.
- Is AssetronX affiliated with the certifying body?
- No. AssetronX is an independent examination-preparation provider and is not affiliated with, endorsed by or accredited by any certifying body. The questions are our own; the publications they refer to are not.
A shop proposes to drop its weekly laboratory checks of in-use penetrant chemistry because a monitor panel is run every shift. Why is this unacceptable?
Worked answers
All ten ASNT Liquid Penetrant Testing - Level I & II questions with the correct option, why it is correct and the paragraph it comes from. Attempt them above first — the reasoning is worth more than the key.
Show the ten answers and their references
- Q1 · ASNT PT I-II · Closed book
A shop proposes to drop its weekly laboratory checks of in-use penetrant chemistry because a monitor panel is run every shift. Why is this unacceptable?
- A. Monitor panels may only be run monthly
- B. The panel checks equipment but never responds to changes in the chemical materials themselves
- C. Laboratory checks are needed solely to satisfy customer paperwork and add no technical value, so both practices are optional if a written procedure says so
- D. Panels expire after ten uses
- E. The panel flags only sudden major shifts and does not substitute for periodic material and equipment checks ✓
Routine panel runs complement rather than replace the scheduled examination of penetrant chemistry, gages, nozzles and other hardware, because gradual deterioration escapes the panel. NDT Handbook Vol 2, Chapter 8 Part 3 - Limitations of the System Monitor Panel
- Q2 · ASTM E1417 · Closed book
When interpreting weekly refractometer readings from a hydrophilic remover bath, what should the readings be compared against to establish the true bath concentration?
- A. Readings taken from the lipophilic emulsifier used elsewhere in the facility
- B. A fixed conversion table published in the standard
- C. Values measured from prepared solutions of known emulsifier concentration ✓
- D. The nominal value stamped on the refractometer body
- E. The refractive index printed on the water supply certificate
A curve built from known concentrations of the same product converts refractive index into bath strength; no universal table covers every emulsifier. ASTM E1417 Section 7.8.2.6
- Q3 · ASNT PT I-II · Closed book
Broad, shallow discontinuities are suspected on a machined component. Why is a water washable penetrant a questionable choice for this job?
- A. Rinsing can strip penetrant back out of shallow surface entrapments ✓
- B. The dye cannot enter wide shallow openings
- C. Water reacts with the dye and bleaches it before the developer can be applied, so contrast is permanently destroyed
- D. Shallow flaws always require visible dye
- E. Dwell time would become far too long
Because the emulsifying agent is built into a water washable penetrant, the rinse acts on penetrant everywhere, including inside broad shallow flaws, so overwashing can remove the very entrapments being sought. ASNT PT Level II Study Guide, Chapter 2 - Water Washable Method
- Q4 · ASTM E165 · Closed book
An open dip tank of hydrophilic emulsifier is in daily use. How does ASTM E165 expect its concentration to be controlled?
- A. Verified only when the bath is first mixed
- B. Tracked continuously with a conductivity probe
- C. Determined monthly by titrating a bath sample against a standard solution in the laboratory
- D. Judged by the color of the bath each shift
- E. Checked every week with a suitable refractometer ✓
Water-base removers are diluted concentrates whose strength drifts with use and evaporation, so a weekly refractometer reading keeps the removal action consistent. ASTM E165 Section 7.3.2.1
- Q5 · ASME V · Closed book
A part must be examined at 150 deg F. What does Article 6 require?
- A. The work may proceed once a visible dye replaces the fluorescent penetrant
- B. The work may proceed if dwell time is doubled to suit the heat
- C. The work is prohibited outright at any temperature above the standard band
- D. The work may proceed if the surface is cooled with forced air while dwelling continues
- E. The materials and processing must be qualified through Mandatory Appendix III ✓
Stepping outside the standard band is permitted, but only after the proposed temperature has been qualified by the comparator block route that appendix lays down. ASME V Article 6 T-653
- Q6 · ASTM E1316 · Closed book
In ASTM E1316 penetrant terminology, the portion of the dwell period during which excess penetrant or emulsifier runs off the part is defined as the:
- A. rinse time
- B. wash
- C. drain time ✓
- D. development interval
- E. drying time
Drain time is a defined slice of the dwell period; drying time refers to a cleaned, rinsed, or wet-developed part losing its moisture, and wash means removal with another liquid. ASTM E1316 Section F - Liquid Penetrant Testing Terms
- Q7 · ISO 3452.4 · Closed book
At the emulsifier station of a fixed line, which application technique does ISO 3452-4 permit for a lipophilic emulsifier?
- A. Brushing it over the penetrant covered surface, working it in until the background fluorescence disappears completely
- B. Flow-on application from a hose
- C. Foam application
- D. Dilute spray application
- E. Immersion of the whole component for a controlled time, followed by draining ✓
Because a lipophilic emulsifier starts diffusing into penetrant on contact and cannot be agitated or scrubbed, dipping with timed drainage is the only sanctioned technique; foam and flow-on are reserved for hydrophilic products. ISO 3452-4 Section 5.5.3
- Q8 · ISO 3452.2 · Closed book
Under ISO 3452-2, how is the sensitivity of each new production batch of a penetrant product verified?
- A. By a full requalification on all four panel thicknesses of the type 1 reference block
- B. By checking it side by side against the retained sample approved earlier ✓
- C. By the customer's incoming inspection department
- D. By a fluorimeter reading alone
- E. By an independent ISO/IEC 17025 laboratory on every batch
Type testing happens once at an independent laboratory; each later batch only needs to match the sample retained from the approved material. ISO 3452-2 Clause 5.4.1
- Q9 · ISO 3452.1 · Closed book
A test report cites the product family designation ISO 3452-2 IAa Level 2. What does the middle character of the code IAa indicate about the process?
- A. A solvent wipe removes the excess
- B. The developer is applied in dry powder form
- C. A lipophilic emulsifier is used for removal
- D. Water is used to remove the excess penetrant ✓
- E. A hydrophilic emulsifier is applied after a water pre-wash
Within the family code the first character gives the penetrant type, the second the removal method and the third the developer form; here the removal method is plain water. ISO 3452-1 Clause 6.4 and Table 1
- Q10 · ISO 3452.5 · Closed book
A product set is marked ICa-2/M in accordance with ISO 3452-5. What does the temperature suffix M convey?
- A. The remover is a methanol based product
- B. The products are qualified for use from 50 deg C up to 100 deg C ✓
- C. The products are qualified for 100 deg C to 200 deg C, proven at three separate test points
- D. The working range was set by the manufacturer between declared limits
- E. The system has a medium sensitivity rating
A temperature suffix added after the sensitivity level shows the qualified hot range; the medium rating spans 50 deg C to 100 deg C with test points at both range limits. ISO 3452-5 Clauses 7 and 12, Table 1
630 more like these
Plus 5 full-length mock exams in the two-section shape of the real day, study mode with instant feedback, and timed practice.
Other certifications in this family
- ASNT Ultrasonic Testing - Level III
- ASNT Radiographic Testing - Level III
- ASNT Magnetic Particle Testing - Level III
- ASNT Liquid Penetrant Testing - Level III
- ASNT Visual Testing - Level III
- ASNT Magnetic Particle Testing - Level I & II
- ASNT NDT Level III - Basic Examination
- ASNT Radiographic Testing - Level I & II
- ASNT Ultrasonic Testing - Level I & II
- ASNT Visual Testing - Level I & II
AssetronX is an independent examination-preparation provider, not affiliated with, endorsed by or accredited by API, AMPP, NACE, ASNT, CSWIP, IASSC, SHRM, PMI, CIPS or any certifying body. Questions are our own work; the publications they refer to are not.