API 936 REFRACTORY PERSONNEL · PUBLICATION

API 975 in the API 936 Refractory Personnel exam

Refractory Installation Quality Control— Inspection and Testing of Refractory Brick Systems and Materials. Our API 936 Refractory Personnel bank draws 216 of its 1,848 questions from this publication — 12% — and they cite 103 different clauses. The clause list below is counted from those questions, not copied from a syllabus.

Clauses the questions cite

The 40 most cited of 103, in document order. The number is how many questions in our bank reference that clause.

3.1 · 23.2 · 13.3 · 13.4 · 13.5 · 13.7 · 23.8 · 23.9 · 13.10 · 23.11 · 13.12 · 13.13 · 13.14 · 13.15 · 13.16 · 13.17 · 13.19 · 23.20 · 23.21 · 13.22 · 23.23 · 13.24 · 13.25 · 13.26 · 13.27 · 13.28 · 13.29 · 23.30 · 13.31 · 13.32 · 13.33 · 13.34 · 14.1.1 · 14.1.2 · 14.1.3 · 24.1.4 · 24.1.5 · 24.1.6 · 14.1.7 · 14.1.8 · 1

What they ask about

Defect Criteria - 975-MATL 6Workmanship - 975-QC 5Mortar Workmanship - 975-QC 5Manufacturer responsibilities 4Terminology - 975-MATL 4Pre-shipment Testing - 975-QC 4Workmanship Scenario - 975-QC 4Fireclay brick classification 3Inspector responsibilities 3Expansion materials 3Gravity wall design 3Property Limits 3Terminology - 975-QC 3Owner Responsibilities - 975-ROLES 3Dimensional Tolerances - 975-MATL 3Support Design - 975-QC 3Wall Construction - 975-QC 3Mortar Scenario - 975-QC 3

Free sample questions from API 975

  1. What defines an independent laboratory in refractory testing?

    • A. Facility owned by contractor
    • B. Facility owned by manufacturer, since nothing else is thought to bear on the question
    • C. Facility not affiliated with contractor or manufacturer ✓
    • D. Owner’s in‑house lab
    • E. Government lab only

    Independent laboratory is a testing facility not affiliated with manufacturer or contractor. API 975, 3.14

  2. As per API 975, what is the maximum permitted fin height at corners and edges of dense firebrick?

    • A. 1.0 mm (0.04 in.)
    • B. 2.0 mm (0.08 in.)
    • C. 3.0 mm (1/8 in.) ✓
    • D. 5.0 mm (0.20 in.)
    • E. 10.0 mm (0.39 in.)

    Fins at corners and edges shall not exceed 3.0 mm (1/8 in.) in height on dense firebrick. Fins are a manufacturing defect appearing as fin shaped projections along the outer surface of the brick. API 975, 5.2.7

All free API 936 Refractory Personnel questions

Other publications in this exam

1,848 API 936 Refractory Personnel questions

Counts are from AssetronX’s own question bank and describe what we have written, not what the exam contains. AssetronX is an independent examination-preparation provider and is not affiliated with, endorsed by or accredited by any certifying body or standards organisation. The clause numbers refer to the publications’ own paragraphs; the publications themselves are not reproduced here.