ASNT MAGNETIC PARTICLE TESTING - LEVEL III · PUBLICATION
ASTM.E1444 in the ASNT Magnetic Particle Testing - Level III exam
ASTM E1444 E1444M Standard Practice for Magnetic Particle Testing. Our ASNT Magnetic Particle Testing - Level III bank draws 128 of its 804 questions from this publication — 16% — and they cite 51 different clauses. The clause list below is counted from those questions, not copied from a syllabus.
Clauses the questions cite
The 40 most cited of 51, in document order. The number is how many questions in our bank reference that clause.
What they ask about
Free sample question from ASTM.E1444
An MT facility with a stable, well documented bath maintenance history has a Level III who proposes lengthening the wet particle contamination check from weekly to monthly. Under ASTM E1444 Table 1, this change is:
- A. Permissible when substantiated by actual technical or reliability data ✓
- B. Prohibited unless the facility converts to aerosol can suspensions
- C. Permissible with a customer verbal concurrence
- D. Permissible only after revising the practice through ASTM ballot
- E. Prohibited, because Table 1 intervals are absolute maximums that no facility may ever exceed under any circumstance whatsoever
A footnote to the process control table allows verification intervals to be shortened or lengthened when genuine technical or reliability data support the change. ASTM E1444 Table 1
All free ASNT Magnetic Particle Testing - Level III questions
Other publications in this exam
Counts are from AssetronX’s own question bank and describe what we have written, not what the exam contains. AssetronX is an independent examination-preparation provider and is not affiliated with, endorsed by or accredited by any certifying body or standards organisation. The clause numbers refer to the publications’ own paragraphs; the publications themselves are not reproduced here.