ASNT LIQUID PENETRANT TESTING - LEVEL I & II · PUBLICATION
ASTM.E165 in the ASNT Liquid Penetrant Testing - Level I & II exam
ASTM E165 E165M Standard Practice for Liquid Penetrant Testing. Our ASNT Liquid Penetrant Testing - Level I & II bank draws 106 of its 630 questions from this publication — 17% — and they cite 50 different clauses. The clause list below is counted from those questions, not copied from a syllabus.
Clauses the questions cite
The 40 most cited of 50, in document order. The number is how many questions in our bank reference that clause.
What they ask about
Free sample question from ASTM.E165
An open dip tank of hydrophilic emulsifier is in daily use. How does ASTM E165 expect its concentration to be controlled?
- A. Verified only when the bath is first mixed
- B. Tracked continuously with a conductivity probe
- C. Determined monthly by titrating a bath sample against a standard solution in the laboratory
- D. Judged by the color of the bath each shift
- E. Checked every week with a suitable refractometer ✓
Water-base removers are diluted concentrates whose strength drifts with use and evaporation, so a weekly refractometer reading keeps the removal action consistent. ASTM E165 Section 7.3.2.1
All free ASNT Liquid Penetrant Testing - Level I & II questions
Other publications in this exam
Counts are from AssetronX’s own question bank and describe what we have written, not what the exam contains. AssetronX is an independent examination-preparation provider and is not affiliated with, endorsed by or accredited by any certifying body or standards organisation. The clause numbers refer to the publications’ own paragraphs; the publications themselves are not reproduced here.